Elite High Static Ducted (R32)

Enquire Now

High Static Pressure Hide Away PACi Inverter+. High heating capacity at -7°C. The ducted systems are the ideal solution for flexible, concealed air conditioning and the optional 200mm spigots ensure simple, hassle-free connection to spiral ductwork.

Model Reference
Nom.
Cool
(kW)

Nom.
Heat
(kW)

Max
Pipe
(m)
EuP Lot 10
Energy Rating

Fuse
(Amps)
In/Out

Pipe
Size
Gas

Pipe
Size
Liquid

Electrical
Supply
Indoor Unit ModelOutdoor Unit ModelSCOPSEER
S-36PF1E5BU-36PE1E5A5.005.60403.905.70161/21/4Single
S-50PF1E5BU-50PE1E5A5.005.60403.905.70161/21/4Single
S-60PF1E5BU-60PE1E5A6.007.00504.006.10205/83/8Single
S-71PF1E5BU-71PE1E5A7.108.00504.006.40205/83/8Single
S-100PF1E5BU-100PE1E5A10.0011.20753.805.80255/83/8Single
S-125PF1E5BU-125PE1E5A12.5014.00753.725.57305/83/8Single
S-140PF1E5BU-140PE1E5A14.0016.00753.635.41305/83/8Single
S-71PF1E5BU-71PE1E8A7.108.00504.006.40165/83/8Three
S-100PF1E5BU-100PE1E8A10.0011.20753.805.80165/83/8Three
S-125PF1E5BU-125PE1E8A12.5014.00753.725.57165/83/8Three
S-140PF1E5BU-140PE1E8A14.0016.00753.635.41165/83/8Three

Features and Benefits

  • Extremely quiet operation from 26 dB(A)
  • Auto restart after power failure
  • Auto changeover
  • Twin, triple and double-twin split options
  • DC FAN for better effi ciency and control
  • Built in drain pump
  • Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The external device can be control by the remote control of the Panasonic indoor unit
  • The unit features air inlet on one side, air outlet on the other side. The air inlet filter can be pulled out from the side of the unit and can be folded.
  • PAC-i Elite Seasonal Inverter
  • ErP Compliant
  • Cooling to -15°C
  • Heating to -20°C
  • R22 Replacement Technology
  • Standard Hardwired Controller CZ-RTC4
  • Other control options available.

Power/Wiring

Panasonic PAC-i systems require a separate power supply to Indoor (3 Amp isolator for all units) and Outdoor Units. It is also possible to supply power to outdoor unit only, and run power to indoor via a 3 core flex from a field supplied fused terminal block. A separate 2 core 0.75mm² screened cable will also be required for data connection

Advanced Technical Data

Indoor Units

Indoor Unit Technical Data
ModelS-36PN1E5AS-50PN1E5AS-60PN1E5AS-71PN1E5AS-100PN1E5AS-125PN1E5AS-140PN1E5A
Cooling (kW) - Nominal3.605.006.007.1010.0012.5014.00
Heating (kW) - Nominal4.005.607.008.0011.2014.0016.00
Cooling (kW) - Max SEER Condition4.005.607.108.0012.5014.0015.50
Heating (kW) - Max SCOP Avg °C5.006.508.009.0014.0016.0018.00
Sensible Heat Ratio (SHR)3.504.405.606.109.7010.5011.20
Sound Pressure Level (dBA)33/29/2534/30/2635/32/2638/34/3139/35/3240/36/3335/32/26
Height - mm (grille)290
Width - mm (grille)80010001400
Depth - mm (grille)700
Weight - kG (grille)29324141
Supply Air Plenum (mm)TBC x 186TBC x 186TBC x 186
Return Air Plenum (mm)592 x TBC792 x TBC1192 x TBC
External Static Pressure (Pa)70 (10 - 150)100 (10 - 150)
Air Flow Rate (m³/min)14/13/1016/15/1221/19/1532/26/2134/29/2336/32/25
Fused Spur (A)5.00

Single Phase Condensing Units

Outdoor Unit Technical Data
ModelU-36PZH2E5U-50PZH2E5U-60PZH2E5U-71PZH2E5U-100PZH2E5U-125PZH2E5U-140PZH2E5
CombinationsSingleSingleSingleTwinTwin/TripleTwin/Triple/QuadTwin/Triple
Height (mm)6959961416
Width (mm)875940940
Depth (mm)320340340
Weight (kG)4343446899
Airflow (m3/min) Cool/Heat40/4040/4540/4561/60118/108125/112129/116
Sound Pressure Cooling (dBA)43454648525354
Liquid (mm(inches))6.35 (1/4)9.52 (3/8)
Gas (mm(inches))12.7 (1/2)15.88 (5/8)
Max Pipe Run (m)405085
Max Pipe Lift (m)30 (15 if condenser is lower than IU)
Pre-charged to (m)30
Standing Charge (kG)1.151.151.451.953.05
RefrigerantR32
Add Charge p/metre (g)
20203545454545
PhaseSingle
Power Supply toIU (5A) and OU or OU with feed to IU
Max Current (A)111216.417.5242728
Run Current (A)3.25.256.957.99.9514.518
Fuse Rating (A)20202525303535
Interconnecting2C Screen 0.75mm²
Twin Pipe KitCZ-P224BK2BM
Triple Pipe KitNo CombinationCZ-P3HPC2BM

Three Phase Condensing Units

Outdoor Unit Technical Data
ModelU-71PZH2E8U-100PZH2E8U-125PZH2E8U-140PZH2E8
CombinationsTwinTwin/TripleTwin/Triple/QuadTwin/Triple
Height (mm)9961416
Width (mm)940940
Depth (mm)340340
Weight (kG)6810199101
Airflow (l/s) Cool/Heat1016-10001967-18002084-18672150-1934
Sound Pressure Cooling (dBA)48525354
Liquid (mm(inches))9.52 (3/8)
Gas (mm(inches))15.88 (5/8)
Max Pipe Run (m)5075
Max Pipe Lift (m)
Pre-charged to (m)30
Standing Charge (kG)1.953.05
RefrigerantR32
Add Charge p/metre (g)
45
PhaseThree
Power Supply toIU (5A) and OU or OU with feed to IU
Run Current Cool/Heat (A)2.80 - 2.903.65 - 3.855.40 - 5.206.75 - 6.50
Fuse Rating (A)16161616
Interconnecting2C Screen 0.75mm²
Twin Pipe KitCZ-P224BK2BM
Triple Pipe KitNo CombinationCZ-P3HPC2BM