MAH4 – AHU Connection Kit (R32/410a)

Enquire Now

Air Handling Unit Kit

AHU connection kit connects outdoor units to air handling units system. Combines air conditioning and fresh air in just one solution

Application: Hotels, offices, server rooms or all large buildings where air quality control such as humidity control and fresh air and is needed

* To be simultaneous operation controlled by one remote controller sensor.

Model Reference
Nom.
Cool
kW(HP)

Nom.
Heat
kW(HP)

Pipe
Length (m)

Pipe
Gas

Pipe
Liquid
Indoor UnitMinMax kW/HP
116EEVPACK12.40 (4)22.40 (8)12.50 (4)25.00 (8)10-1005/83/8
133EEVPACK28.00 (10)33.50 (12)28.00 (10)37.50 (12)10-1007/83/8
145EEVPACK44.80 (16)61.50 (22)50.00 (16)69.00 (22)10-1001 1/81/2
156EEVPACK67.00 (24)78.40 (28)78.40 (24)88.00 (28)10-1001 1/81/2
174EEVPACK84.00 (30)134.00 (48)134.00 (30)150.00 (48)10-1001 3/85/8

The Panasonic AHU connection kits offer a wealth of connectivity possibilities so can be easily integrated into many systems.
Besides the advantages in terms of indoor air quality, air conditioning offers also an energy saving potential. For example, while uncontrolled ventilation through open windows leads to large amounts of heat being lost to the outside during the heating season or gained from the outside during the cooling season, air conditioning systems provide possibilities to utilize the extra “free”
energy in heat recovery modules so that overall operating costs will be reduced.
The larger area of the comfort range, the better the energy saving opportunities.

  • Maximum capacity / system: 48 HP (134 kW*)
  • Selectable expansion valve packs depending on the capacity
  • DC 12 V outlet available without optional interface
  • Maximum elevation difference indoor/outdoor unit: 10 m
  • Elevation difference (indoor unit / indoor unit): 4 m
  •  In / out connection capacity ratio: 50~100%
  •  Maximum number of AHU connection kits: 1 unit
  • Outdoor temperature range in heating: ‑20 ~ +15 °C
  • Available temperature range for the suction air at AHU connection kit: cool: +18 ~ +32 °C / heat: +16 ~ +30 °C
  • The system’s set temperature can be selected either as the default setting discharge air temperature (supply room temperature) or the suction air set temperature (or
    room return air temperature)
  • Accurate control with a pressure transducer
  • Direct Modbus communication with a built‑in Modbus S‑Link interface
  • Various technical parameters available with Modbus
  • SG Ready fulfilled. Demand input can be set Thermostat OFF or 40 ~ 200% by the user
  • Defrost operation signal, compressor status ON / OFF output
  • Display an error message concerning drain water overflow
  • Connectable with S‑Link system. Special care for electrical noise may be necessary depending on the on‑site system
  • Fan control signal output to manage the air flow (ON / OFF)
  • Alarm status monitoring output