Logicool Air Conditioning

sales@logicool-ac.com

Results for {phrase} ({results_count} of {results_count_total})
Displaying {results_count} results of {results_count_total}
Generic filters
Exact matches only
Search in title
Search in content
Search in excerpt
01283 218277
  • Hitachi
    • RAC Domestic
    • Primairy Light Commercial
    • Multi Splits
    • IVX Light Commercial
    • Set-Free VRF
    • Ventilation
    • Yutaki Air to Water
    • Controls
    • Fault Codes
  • Mitsubishi Electric
    • M Series Split Systems
    • Multi-Splits
    • Mr. Slim Split Systems
    • City Multi VRF Systems
    • IT Cooling
    • Ventilation
    • Refrigeration
    • Ecodan Heating
    • Controls
    • Fault Codes
  • Panasonic
    • Light Commercial
    • Free Multi
    • Low Temperature Cooling
    • PAC-i Commercial Split Systems
    • ECO-i-VRF Systems
    • Nanoe-X Products
    • Ventilation
    • Aquarea Air to Water
    • CO2 Refrigeration
    • ECO-w Chillers
    • Controls
    • Fault Codes
  • Clivet
    • Domestic Air Source Heat Pumps
    • Commercial Heat Pump Chillers
  • Parts & Spares
  • Downloads
  • Forms
    • Account Application (F-Gas Registered)
    • Account Application (Heating Companies)
    • Site Visits
    • Warranty Enquiry
  • About Us & Contacts
    • Case Studies

Product Information

  • Panasonic
  • Product Catalogue
    • Light Commercial
    • Free Multi
    • Low Temperature
    • PAC-i Commercial Split Systems
    • Nanoe-X Products
    • ECO-i-VRF Systems
    • Ventilation
    • Aquarea Air to Water
    • CO2 Refrigeration
    • ECO-w Chillers
    • Controls

Home » Panasonic Aquarea Air to Water » J Series T-CAP (60°C) Monobloc

J Series T-CAP (60°C) Monobloc

Enquire Now

NEW PANASONIC AQUAREA T-CAP MONO-BLOC J GENERATION

32 For retrofit and new builds, Aquarea T-CAP is the ideal solution for those installations where the output capacity is demanding

AQUAREA T-CAP MONO-BLOC J GENERATION PROVIDES BOTH DOMESTIC HOT WATER AND HEAT FOR RADIATORS AND UNDERFLOOR HEATING FROM ONE OUTDOOR UNIT

Ideal to ensure that the heating capacity is maintained even at very low temperatures.

This line-up is able to maintain the heat pump output capacity until -20 °C outdoor temperature without the help of an electrical booster heater

Sales information Operational Manual Service manuals Installation manual OU Dimensions
Model ReferenceRated Heat Output (kW)System COP
Min
Flow
Rate (l)

Electric
Heater
Cap (kW)

Fuse (Amps)

Electrical Supply
Outdoor UnitA-7/W35A2 /W35A7/W35A-7/W35A2 /W35A7/W35A7/W35
WH-MXC09J3E59.009.009.003.083.815.0825.80330 / 30Single
WH-MXC12J6E512.0012.0012.002.823.534.8034.40630 / 30Single
WH-MXC09J6E89.009.009.003.083.815.0825.80320 / 16Three
WH-MXC12J9E812.0012.0012.002.823.534.8034.40920 / 20Three
WH-MXC16J9E816.0016.0016.002.393.104.5245.80920 / 20Three

T-CAP stands for Total Capacity. This line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, regardless of the outside temperature or the water temperature. The MXC adapts well in an existing installation with a boiler backup, and in a new application with underfloor heating, low temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimise the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating or cooling control and management.

Technical focus

Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager.

Optional Smartphone control

Range from 9 to 16kW, Single and Three Phase

Maximum hydraulic module output temperature: 55°C

Works at temperatures as low as -20°C

Cooling temperature range 5 ~ 20°C

 

Advanced Technical Data

Single Phase Models

Single PhaseThree Phase
Outdoor UnitWH-MXC09H3E5WH-MXC12H6E5WH-MXC16H9E5
Heating capacity at +7°C (heating water at 35°C)kW9,0012,0016,00
COP at +7°C (heating water at 35°C)W/W4,844,744,28
Heating capacity at +2°C (heating water at 35°C)kW9,0012,0016,00
COP at +2°C (heating water at 35°C)W/W3,593,443,10
Heating capacity at -7°C (heating water at 35°C)kW9,0012,0016,00
COP at -7°C (heating water at 35°C)W/W2,852,722,49
Cooling capacity at 35°C (cooling water at 7°C)kW7,0010,0012,20
EER at 35°C (cooling water at 7°C)W/W3,172,812,56
Energy Efficiency Class at 35°CA++A++A++A++
Energy Efficiency Class at 55°CA++A++A++A++
Sound power levelHeating / CoolingdB68 / 6769 / 6872 / 71
DimensionsH x W x Dmm1.410 x 1.283 x 3201.410 x 1.283 x 3201.410 x 1.283 x 320
Weightkg142142164
Refrigerant (R410A)¹kg / TCO2 Eq.2,30 / 4,8022,30 / 4,8022,35 / 4,907
Water pipe connectorR 1R 1R 1

Pump
Number of speedsVariable Speed
Input power (Min / Max)W32 / 10234 / 11034 / 110
Heating water flow (?T=5 K. 35°C)l/min25,834,434,4
Capacity of integrated electric heaterkW366

Input Power
HeatingkW1,862,533,74
CoolingkW2,213,564,76

Running and Starting current
HeatingA8,811,75,7
CoolingA10,416,57,1
Current 1A29,029,015,5
Current 2A13,026,013,0
Recommended FuseA30 / 3030 / 3016 / 16
Recommended cable size, supply 1 & 2mm²3 x 4,0 or 6,0 / 3 x 4,03 x 4,0 or 6,0 / 3 x 4,05 x 1,5 / 5 x 1,5
Operation rangeOutdoor ambient°C-20 ~ +35

Water outlet
Heating°C20 ~ 60
Cooling°C5 ~ 20

 

 

 

 

Back to products
Add selected to wishlist
Green Dot    Energy    Blue Dot    Air conditioning     Red Dot    Heating
©Logicool Air Conditioning & Heat Pumps Limited.
Unit 1, Highwall Business Park,
Tetron Way,
Swadlincote, DE11 0AF.
• T 01283 218277    • F 01283 229352    • E sales@logicool-ac.com
ACR 2013 Finalist
  • Terms & Conditions
  • Privacy Policy
  • Cookies
Product Enquiry