Precise Cooling Perimetral

Enquire Now

 Panasonic Close Control and Vertical DX units

Close Control units provide a strict control of environmental conditions such as temperature, humidity in data centers, laboratories, and other applications where sensitive equipment or processes require stable and controlled conditions.
Vertical DX units can be used in industries, data centers and tertiary application thanks to their high reliability, high efficiency and low noise level.

 Introducing the P Series – Perimetral · R32 system. Our first complete package solution for critical environment up to 21 kW utilsing PAC-i ELITE Condensing Units enabling shorter lead times

Indoor Unit Technical Data
SIZE00710111012101410211
System Type Options
UpflowXXXXX
DownflowXXXXX
Compatible CondensersU-71PZH4E5(8)U-100PZH4E5(8)U-125PZH4E5(8)U-140PZH4E5(8)U-250PZH4E8
Cooling (kW) *7.449.9212.5014.7120.47
Sensible Cooling (kW) *6.898.4110.6712.6020.47
EER (Nominal) **3.523.132.792.612.38
Sound Pressure Level (dBA) ~5159595956
Height - mm19901990199019901990
Width - mm750750750860860
Depth - mm600600600600800
Weight - kG150200205205225
Nominal Air Flow Rate (m³/hr)22003500350035007000
Power SupplySingle Phase (220-240v/50Hz/1Ph)
Fused Spur (A)TBC
* Performance refers to: intake air 24 °C-45%Rh; R410A refrigerant; condensing temperature 45 °C; water temperature 7/12 °C; external static pressure 30 Pa. The declared performance does not consider the
heat generated by the fans, which must be added to the thermal load of the system. **) EER (energy efficiency ratio) = total cooling capacity / input power of compressors + input power of fans (excluding aircooled
condensers). ~) Sound pressures at a distance of 2 m; in a free field; pursuant to UNI EN ISO 3744:2010. 4) Outdoor unit located lower / outdoor unit located higher. 3) Pipe length up to 30 m.

 
Compatible products


 
The Range at a glance

  • Smart solution for precise cooling in smaller critical cooling environment by combining a Panasonic PACi NX ELITE condensing unit (from stock) with Tecnair P Series DX unit.
  • The technical characteristics of this solution make it ideal for applications such as: museums, archives and control rooms.

Features and Benefits/Inclusions

  • Electrical power control panel with main switch door lock and microprocessor terminal
  • Main Microprocessor Controller
  • Supply fan section: consisting of one or more Plug Fan EC brushless electric fans (with electronic regulation) fixed to the machine’s structure.
  • Filtering section: self-extinguishing non-regenerable filters; the machine includes provision for the use of a differential pressure probe to allow display of the clogged filter warning signal.
  • Cooling circuit (direct expansion versions): consisting of a direct expansion coil with expanded copper pipes inside aluminium
    fins and hot-dip galvanised steel sheet structure, copper cooling circuit with anti-condensation thermal insulation,
    pressure probes for monitoring low pressure and high pressure, temperature probes for controlling temperature of intake,
    of the liquid and compressor discharge, high pressure manual reset safety sensor (PS HP 41 BarG).
  • Compatible with Panasonic Central Controllers/P-Link

Optional Accessories

  • Electric modulating post-heating coil
  • Immersed electrode humidifier: consisting of a steam production cylinder, charge valve, discharge valve, support and water circuit in plastic.
  • Plenums (Solid Panel, Front Grille, Side Grilles and/or Soundproofed Duct Sections.
  • Adjustable Plinths
  • Condensate Pump

 

Advantages

  • From stock condensing units
  • Short lead times for indoor units
  • High efficiency
  • Full function as standard
  • Strict control of room temperature and humidity
  • Low GWP refrigerant R32
Back to products