Logicool Air Conditioning

sales@logicool-ac.com

01283 218277
  • Hitachi
    • RAC Domestic
    • Light Commercial
    • Global PAC Primary
    • IVX Light Commercial
    • Set-Free VRF
    • Ventilation
    • Yutaki Heating
    • Chillers
    • Fault Codes
  • Mitsubishi Electric
    • M Series
    • Multi-Splits
    • Mr. Slim
    • City Multi
    • IT Cooling
    • Lossnay
    • Ecodan
    • e-Series Chillers
    • Controls
    • Fault Codes
  • Panasonic
    • Light Commercial
    • Free Multi
    • Low Temperature Cooling
    • PAC-i Commercial Split Systems
    • ECO-i-VRF Systems
    • Nanoe-X Products
    • Ventilation
    • Aquarea Air to Water
    • CO2 Refrigeration
    • ECO-w Chillers
    • Controls
    • Fault Codes
  • Parts & Spares
  • News
  • Careers
  • Downloads
  • About Us
  • Contact

Product Information

  • Panasonic
  • Product Catalogue
    • Light Commercial
    • Free Multi
    • Low Temperature
    • PAC-i Commercial Split Systems
    • Nanoe-X Products
    • ECO-i-VRF Systems
    • Ventilation
    • Aquarea Air to Water
    • CO2 Refrigeration
    • ECO-w Chillers
    • Controls
panasonic premier rewards
panasonic warranties

Home » Products » Panasonic Aquarea Air to Water » H Generation T-CAP (55°C) Monobloc

H Generation T-CAP (55°C) Monobloc

The MXC is ideal for residential properties which don’t have an external boiler and require a maintained capacity level.

Sales information Installation manual
Model ReferenceRated Heat Output (kW)System COP
Electric
Heater
Cap (kW)

Fuse (Amps)

Electrical Supply
HWCOutdoor UnitA-7/W35A2 /W35A7/W35A-7/W35A2 /W35A7/W35





Field
Supply/
Panasonic
WH-MHF09H3E59.009.009.002.853.594.84330 / 30Single
WH-MHF12H6E512.0012.0012.002.723.444.74630 / 30 Single
WH-MHF12H9E812.0012.0012.002.493.104.28916 / 16 Three

T-CAP stands for Total Capacity. This line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, regardless of the outside temperature or the water temperature. The MXC adapts well in an existing installation with a boiler backup, and in a new application with underfloor heating, low temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimise the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating or cooling control and management.

Technical focus

Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager.

Optional Smartphone control

Range from 9 to 16kW, Single and Three Phase

Maximum hydraulic module output temperature: 55°C

Works at temperatures as low as -20°C

Cooling temperature range 5 ~ 20°C

 

Advanced Technical Data

Single Phase Models

Single PhaseThree Phase
Outdoor UnitWH-MXC09H3E5WH-MXC12H6E5WH-MXC16H9E5
Heating capacity at +7°C (heating water at 35°C)kW9,0012,0016,00
COP at +7°C (heating water at 35°C)W/W4,844,744,28
Heating capacity at +2°C (heating water at 35°C)kW9,0012,0016,00
COP at +2°C (heating water at 35°C)W/W3,593,443,10
Heating capacity at -7°C (heating water at 35°C)kW9,0012,0016,00
COP at -7°C (heating water at 35°C)W/W2,852,722,49
Cooling capacity at 35°C (cooling water at 7°C)kW7,0010,0012,20
EER at 35°C (cooling water at 7°C)W/W3,172,812,56
Energy Efficiency Class at 35°CA++A++A++A++
Energy Efficiency Class at 55°CA++A++A++A++
Sound power levelHeating / CoolingdB68 / 6769 / 6872 / 71
DimensionsH x W x Dmm1.410 x 1.283 x 3201.410 x 1.283 x 3201.410 x 1.283 x 320
Weightkg142142164
Refrigerant (R410A)¹kg / TCO2 Eq.2,30 / 4,8022,30 / 4,8022,35 / 4,907
Water pipe connectorR 1R 1R 1

Pump
Number of speedsVariable Speed
Input power (Min / Max)W32 / 10234 / 11034 / 110
Heating water flow (?T=5 K. 35°C)l/min25,834,434,4
Capacity of integrated electric heaterkW366

Input Power
HeatingkW1,862,533,74
CoolingkW2,213,564,76

Running and Starting current
HeatingA8,811,75,7
CoolingA10,416,57,1
Current 1A29,029,015,5
Current 2A13,026,013,0
Recommended FuseA30 / 3030 / 3016 / 16
Recommended cable size, supply 1 & 2mm²3 x 4,0 or 6,0 / 3 x 4,03 x 4,0 or 6,0 / 3 x 4,05 x 1,5 / 5 x 1,5
Operation rangeOutdoor ambient°C-20 ~ +35

Water outlet
Heating°C20 ~ 60
Cooling°C5 ~ 20

 

Accessories

Accessories
PAW-TD20C1E5Tank 200L - Stainless steel
PAW-TD30C1E5Tank 300L - Stainless steel
PAW-TG20C1E3STD-1Tank 200L - Enamelled
PAW-TG30C1E3STD-1Tank 300L - Enamelled
CZ-TK1Temperature sensor for 3rd party tank
PAW-3WYVLV-SI3 way valve
PAW-BTANK50LBuffer tank 50L
PA-AW-WIFI-1TEWifi interface
PAW-A2W-BIVBivalent control
PAW-A2W-RTWIREDRoom thermostat

 

Product Image

Back to products
Add selected to wishlist
Green Dot    Energy    Blue Dot    Air conditioning     Red Dot    Heating
©Logicool Air Conditioning & Heat Pumps Limited.
The Machine House, Newfields, Moira,
Swadlincote, DE12 6EG.

• T 01283 218277    • F 01283 229352    • E sales@logicool-ac.com
ACR 2013 Finalist
  • Terms & Conditions
  • Privacy Policy
  • Cookies